From voltage to your phone, total control
8-channel industrial hardware, AEM Utility software and MQTT cloud: measurements are born in the panel and reach your pocket — with field-updatable firmware.
AEM Utility
Configuration and monitoring software for Windows — Linux coming soon. Connect over USB or RS485 and configure the whole device without touching the local keypad.
AEM Utility Pro
PROYour data beyond the panel: Utility Pro publishes measurements to the cloud over MQTT and you follow everything on your phone — from anywhere.
Multiple devices? Meet the AEM-Hub
A gateway that concentrates up to 31 AEM devices on the RS485 bus and pushes everything to the cloud over MQTT — no PC in the panel.
Choose your measurement range
Three variants sharing the same electronics, firmware and Modbus map — only the input conditioning changes.
Engineered for environments where reliability is not optional
Electrical panels, battery banks, rectifiers and critical DC infrastructure. Opto-isolated inputs, configurable alarms and native SCADA/PLC integration.



Where the AEM-60DC8 operates
Auditable engineering
Wiring diagram
Screw terminals · rear viewComplete technical documentation
Datasheets, Modbus map and simulator for integrators and engineers.
Frequently asked questions
How many DC channels does the AEM-60DC8 monitor simultaneously?
The AEM-60DC8 monitors 8 independent DC channels in parallel, with configurable polling rate and 5000 VAC rms galvanic isolation across the 8 opto-isolated digital inputs. Each channel reads 0 to 60 V DC with ±1% FS accuracy.
Is the AEM-60DC8 compatible with my SCADA or PLC?
Yes. The AEM-60DC8 communicates over Modbus RTU on RS-485 at 4800, 9600, 19200, 57600, and 115200 bps. Modbus ID is set via DIP switch. It is compatible with Ignition, Elipse E3, AVEVA InTouch, WinCC, and any standard Modbus RTU client.
How is the AEM-60DC8 firmware updated in the field?
AEM-60DC8 v1.03 includes a built-in USB bootloader. Firmware is digitally signed with Ed25519 and validated through 9 layers before acceptance, protecting against forged firmware, downgrade attacks, and field interruption (anti-brick by construction).
Is the AEM-60DC8 aligned to IEC 62443?
The AEM-60DC8 is aligned to IEC 62443-4-2: the product implements security controls aligned to that standard (signed firmware, anti-rollback, anti-brick, forensic telemetry, secure defaults).
Where can I find the complete AEM-60DC8 Modbus register map?
The AEM-60DC8 exposes 147 holding registers organized in 17 functional blocks (voltages, alarms, configuration, forensic telemetry, identification). The complete map is documented in the datasheet and at aem.lri.com.br/en-us/modbus, with a Python simulator available for download.