Tech blog

Blog

Field-oriented posts for automation and telecom engineers — practical guides, comparisons and case studies built around the AEM-60DC8.

The complete Modbus RTU guide for field engineers

Modbus RTU technical guide: frame, function codes, holding registers, RS-485, exception debugging, and industrial installation best practices.

modbusindustrial-automationrs-485
12 min

Modbus RTU Simulator in Python: a step-by-step tutorial for SCADA integrators

Practical tutorial for building a Modbus RTU simulator in Python and validating SCADA integration with the AEM-60DC8 before the hardware ships.

modbuspythonsimulator

Ed25519 signed firmware: why it matters on the factory floor

Why Ed25519 digital signatures on firmware matter in industrial environments: attacks they prevent, chain of trust, signing ceremony and a checklist for PLC and HMI vendors.

industrial-cybersecurityfirmwareed25519

How to size a DC monitor for a 24/7 industrial panel

Field guide for automation engineers sizing channels, voltage range, polling, isolation and environment of a DC monitor in a 24/7 industrial panel.

dc-monitoringsizingindustrial-panel

Modbus RTU vs Modbus TCP: how to decide without falling for myths

Technical comparison between Modbus RTU and Modbus TCP across physical layer, frame, latency, security, cost and real scenarios, with decision matrix and the role of the AEM-60DC8.

modbus-rtumodbus-tcpindustrial-automation

Modbus data types explained — coils, discrete inputs, input registers and holding registers

Modbus data types in practice: coils, discrete inputs, input registers and holding registers, addressing, function codes and real field pitfalls.

modbusholding-registersindustrial-automation

Persistent anti-rollback in industrial firmware: why it matters

How persistent anti-rollback counters in industrial firmware block downgrade attacks, why digital signatures alone are not enough, classical mechanisms (TAMP, OTP, RTC), versioning policy, and how the AEM-60DC8 implements it.

industrial-cybersecurityfirmwareanti-rollback

Solar string monitoring over Modbus RTU: from voltage divider to SCADA

How to measure, alarm and integrate string-by-string in a solar plant using RS-485, resistive dividers and Modbus RTU, with the common design pitfalls.

solar-pvsolar-stringsmodbus-rtu

16×4 LCD vs touchscreen HMI in industrial panels: when each one belongs

Technical comparison between 16×4 character LCD with 3 keys and touchscreen HMI in industrial panels: total cost, reliability, cybersecurity and application decision matrix.

lcd-16x4touchscreen-hmiindustrial-panel

Case study: monitoring a 48 V rectifier in a Tier III edge data center

How a regional operator of Tier III edge data centers instrumented 48 V rectifiers and a LiFePO4 bank with AEM-60DC8, retired phantom alarms and avoided a battery crash — anonymized illustrative case study.

case-studydata-center48v-rectifier